iC-MSA is a sine/cosine sensor signal conditioner with fail-safe 1 Vpp line driver outputs for low-frequency signals.
The analog PGA front-end takes differential or single-ended signals; current-to-voltage conversion is optional. The signal-path is purely analog from input to output, whereas signal errors are corrected by a digitally-controlled conditioning unit utilizing several D/A converters (includes automatic gain control). Signal loss detection and level monitoring is included.